Product Availability
Every effort is made by COOK to ensure each item listed in the catalog is maintained in stock. Due to the breadth of items listed and the dynamic nature of the product line, COOK does not guarantee all items listed are in stock. If you have any questions, please contact us.
Product Warranty
We warrant that at the time of manufacture, products were prepared and tested in accordance with Quality System Regulations specified by the regulatory bodies in the countries Cook serves and were true to label.
Because of biological differences in individuals, no product is 100% effective under all circumstances. In addition, because we have no control of the condition under which the product is used, diagnosis of the patient, the method of use or administration, and handling of the product after it leaves our possession, we do not warrant either a good effect or against an ill effect following the product’s use. The foregoing warranty is exclusive and in lieu of all other warranties either written, oral or implied (including any warranties of merchantability or fitness for purpose). No representative of the company may change any of the foregoing, and the buyer accepts the product subject to all terms hereof.
Design Changes
COOK reserves the right to change or discontinue any product without notice. Additionally, if the product has been discontinued, we can recommend alternatives.
Product Expiration
Most COOK products carry an expiration date on the label. This date is based on concerns for product integrity and sterility maintenance. An unlimited shelf-life cannot be verified by testing; therefore, some limit must be placed on the life of products. COOK attempts to maximize the shelf-life of our products through testing; however, storage conditions utilized by our customers may affect the length of this period.
Product Storage
COOK products should be stored in a dark, cool and dry place. Extended periods of exposure to light have resulted in degradation of some plastic materials and should be avoided. Extended periods of elevated temperature can reduce the shelf-life of a product and should also be avoided.
Sterilization of Reusable Products
It is the responsibility of the institution that is operating sterilization equipment to validate the equipment. In order to sterilize a reusable product using an autoclave, it must first be properly cleaned and/or disinfected, and then packaged using AAMI recommended practices. During product handling, attention should be taken to coil products in an 8 inch diameter or greater. Do not place the original product packaging in an autoclave cycle; it will not withstand the sterilization temperature. Some products may not be autoclaved. Refer to product instruction or contact customer service for specific parameters regarding autoclave cycle sterilization methods.
Autoclave chamber loading should not exceed 10 products per cubic foot of chamber space or exceed the usable chamber space. If any damage to a product is noted, it should be taken out of service immediately.
-
Cleaning & Sterilization
Cook manufactures sterile and non-sterile medical devices.
Cook's in-house sterilization facility uses an environmentally friendly mixture of ethylene oxide (ETO), as a sterilant. ETO is used because of its compatibility with a wide variety of manufacturing materials, including Tyvek® sealed packaging.
Over the years, Tyvek has proven to be an excellent microbial barrier in maintaining product sterility over shelf life, as long as the package seal is intact and not exposed to hostile environmental storage conditions, including temperatures above 104°F (40°C), a relative humidity above 90% RH, and condensing humidity.
Cook's use of Tyvek sealed packages in our validated industrial sterilization process allows for the efficient processing of the quality products you have come to depend upon as well as our innovative new products. As with most industrial sterilization processes, the sterilization parameters used cannot be duplicated by most institution sterilizers. It is for this reason that we have developed and tested sterilization cycles to achieve a sterility assurance level of 10° for institutions based on AAMI recommended practices for use with our products. AAMI stands for the Association for the Advancement of Medical Instrumentation.
If AAMI Standards and Recommended Practices for sterilization are not available at your institution, you can contact AAMI at 703-525-4890 or 800-332-2264, ext. 217.
Validation is a documented procedure for obtaining, recording, and interpreting the results needed to show that a process will consistently yield a product complying with predetermined specifications.
Tyvek® is a registered trademark of E.I. DuPont® de Nemours & Co.
-
Sterilization of Disposable and Reusable Products Using Ethylene Oxide
It is the responsibility of the institution that is operating sterilization equipment to validate that equipment. In order to sterilize a reusable Cook product using ETO, it must first be properly cleaned and/or disinfected according to product instructions and then packaged using AAMI recommended practices. During product handling, attention should be taken to coil products in an 8 inch diameter or greater. Disposable products either accidentally opened and not used and/or ordered non-sterile may be sterilized one time only. Some products may not be ETO sterilized. Refer to product instructions or contact customer service for the proper sterilization method. Table 1 shows the recommended ETO sterilization cycle parameters:
TABLE I - ETO CYCLE PARAMETERS PARAMETER SET POINT Pre Vacuum Pressure 2.0 psia (-25.9" Hg Vac) Relative Humidity 60% RH Humidity Dwell 20 minutes Chamber Temperature 54.4°C (130°F) Exposure Pressure To Be Determined (1) Exposure Dwell 2 hours ETO Concentration 600 mg/L Post Vacuums 3 Post Vacuum Pressure 2.0 psia (-25.9" Hg Vac) Air Wash (2) 5 minutes Aeration Temperature 54.4°C (130°F) Aeration Dwell 12 hours Air Changes During Aeration 90 per hour ETO sterilizer chamber loading should not exceed 11 products per cubic foot of chamber space or exceed the usable chamber space. If any damage to a product is noted prior to sterilizing, it should be taken out of service immediately.
-
Sterilization of Reusable Products Using An Autoclave
It is the responsibility of the institution that is operating sterilization equipment to validate that equipment. In order to sterilize a reusable Cook product using an autoclave, it must first be properly cleaned and/or disinfected according the product instructions and then packaged using AAMI recommended practices. During product handling, attention should be taken to coil products in an 8 inch diameter or greater. Do not place the original product packaging in an autoclave cycle; it will not withstand the sterilization temperature. Some products may not be autoclaved. Refer to product instructions or contact customer service for the proper sterilization method. Table II shows the recommended autoclave cycle parameters for Cook reusable products.
TABLE II - AUTOCLAVE CYCLE PARAMETERS PARAMETER SET POINT Cycle Type Pre Vacuum Pre Vacuum Pressure 2.5 psia (-24.8" Hg Vac) Chamber Exposure Temperature 132.2°C (270°F) Chamber Exposure Pressure 41.8 psia (27.1 psig) Exposure Dwell 5 minutes Autoclave chamber loading should not exceed 10 products per cubic foot of chamber space or exceed the usable chamber space. If any damage to a product is noted prior to sterilizing, it should be taken out of service immediately.
-
Questions & Answers
A number of questions are frequently asked by customers concerning the sterilization or re-sterilization of Cook products. Some of these questions are answered below.
Disposable Products
Question: Under what conditions should a sterile product labeled as “Disposable - Intended for One-Time Use” / “Disposable - Single Use Only” not be sterilized?
Answer: Cook does not recommend the sterilization of “Disposable - Intended for One-Time Use” / “Disposable - Single Use Only” products that have been used, stored beyond labeled expiration date, or subjected to hostile environmental storage conditions, including temperatures above 104° F (40° C), a relative humidity above 90%, and condensing humidity.
Question: If a sterile product labeled as “Disposable - Intended for One-Time Use” / “Disposable - Single Use Only” is accidentally opened and then not used, can it be sterilized?
Answer: Yes, the product can be sterilized using a validated ethylene oxide sterilization cycle. However, the product must be repackaged using AAMI recommended practices prior to sterilization.
Question: Can “Disposable - Intended for One-Time Use” / “Disposable - Single Use Only” product ordered as non-sterile be sterilized?
Answer: Yes, the product can be sterilized utilizing a validated ethylene oxide sterilization cycle if the product is supplied in a Tyvek pouch or Tyvek sealed tray. Otherwise, it must be repackaged using AAMI recommended practices prior to sterilization.
Question: Can Cook advise me of the ethylene oxide sterilization cycle to use on one of its “Disposable - Intended for One-Time Use” / “Disposable - Single Use Only” products either accidentally opened and not used and/or ordered non-sterile?
Answer: Yes. The cycle parameters for sterilizing disposable products are shown in Table 1 of the ethylene oxide sterilization section of Cleaning and Sterilization and may be used one time only.
Reusable Products
Question: Can the original package in which Cook provides its “reusable” products be ETO sterilized?
Answer: Product provided in a Tyvek pouch or a Tyvek sealed tray may be ETO sterilized. Other Cook packaging configurations must be repackaged using AAMI recommended practices prior to sterilization.
Question: Can the original package in which Cook provides its “reusable” products be placed in an autoclave?
Answer: No, original Cook packaging materials utilized for “reusable” products cannot withstand autoclave cycle parameters.
Question: Can Cook advise me of the proper ethylene oxide sterilization cycle to use on its “reusable” products?
Answer: Yes, Cook has validated an ethylene oxide sterilization cycle that can be used in an institutional setting. However, the product must be properly cleaned and/or disinfected according to product instructions and then packaged using AAMI recommended practices (AAMI, ST41) prior to sterilization.
Question: Can Cook advise me of the autoclave cycle to use in its “reusable” products?
Answer: Yes. Cook has validated an autoclave cycle that can be used in an institutional setting. However, the product must be properly cleaned and/or disinfected according to product instructions and then packaged using AAMI recommended practices (AAMI, SSSA) prior to sterilization.
Question: Can Cook “reusable” products be disinfected by means of cold disinfectants?
Answer: Yes. Cook “reusable” products can be disinfected using cold disinfectants. Refer to cold disinfectant manufacturers instructions for recommended use.
Product Labels
The information provided below is an explanation of reference symbols that can be found on a product label.
Symbol that appears adjacent to the "Catalog/Reorder Number"
Symbol for sterilization using ethylene oxide
Symbol that appears adjacent to the "Manufacturer's Lot Number"
Symbol that appears adjacent to the "Date of Manufacture"
Symbol that appears adjacent to the "Expiration Date"
Symbol that signifies "Do Not Reuse/Single Use Only" for disposable one-time use products
Symbol for "Attention, See Instructions for Use" included
MRI Compatibility
-
Zenith Flex® AAA Endovascular Graft
(excerpted from IFU)
Zenith Flex AAA Endovascular Graft MRI Safety and Compatibility Download
MRI Safety and Compatibility
Non-clinical testing has demonstrated that the Zenith AAA Endovascular Graft is MR Conditional. It can be scanned safely under the following conditions:1.5 Tesla Systems:
- Static magnetic field of 1.5 Tesla
- Spatial gradient field of 450 Gauss/cm
- Maximum whole body averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning
In non-clinical testing, the Zenith AAA Endovascular Graft produced a temperature rise of less than or equal to 1.4 °C at a maximum whole body averaged specific absorption rate (SAR) of 2.8 W/kg, as assessed by calorimetry for 15 minutes of MR scanning in a 1.5 Tesla Magnetom, Siemens Medical Magnetom, Numaris/4 Software, Version Syngo MR 2002B DHHS MR Scanner. The maximum whole body averaged specific absorption rate (SAR) was 2.8 W/kg, which corresponds to a calorimetry measured value of 1.5 W/kg.
3.0 Tesla Systems:
- Static magnetic field of 3.0 Tesla
- Spatial gradient field of 720 Gauss/cm
- Maximum whole body averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning
In non-clinical testing, the Zenith AAA Endovascular Graft produced a temperature rise of less than or equal to 1.9 °C at a maximum whole body averaged specific absorption rate (SAR) of 3.0 W/kg, as assessed by calorimetry for 15 minutes of MR scanning in a 3.0 Tesla Excite, GE Electric Healthcare, G3.0-052B Software, MR Scanner. The maximum whole body averaged specific absorption rate (SAR) was 3.0 W/kg, which corresponds to a calorimetry measured value of 2.8 W/kg.
The image artifact extends throughout the anatomical region containing the device, obscuring the view of immediately adjacent anatomical structures within approximately 20 cm of the device, as well as the entire device and its lumen, when scanned in nonclinical testing using the sequence: Fast spin echo, in a 3.0 Tesla, Excite, GE Electric Healthcare, with G3.0-052B software, MR system with body radiofrequency coil.
For all scanners, the image artifact dissipates as the distance from the device to the area of interest increases. MR scans of the head and neck and lower extremities may be obtained without image artifact. Image artifact may be present in scans of the abdominal region and upper extremities, depending on distance from the device to the area of interest.
Clinical information is available for seventeen patients who received MRI scans after stent-graft implantation. There have been no reported adverse events or device problems in any of these patients as a result of having received an MRI. Additionally, there have been well over 50,000 Zenith AAA Endovascular Grafts implanted worldwide, in which there have been no reported adverse events or device problems as a result of MRI.
Cook Recommends that the patient register the MR conditions disclosed in this IFU with the MedicAlert Foundation. The MedicAlert Foundation can be contacted in the following manners.
Mail: MedicAlert Foundation International
2323 Colorado Avenue
Turlock, CA 95382Phone: 888-633-4298 (toll free)
209-668-3333 from outside the USFax: 209-669-2450 Web: www.medicalert.org -
Cook Celect™ Vena Cava Filter
Non-clinical testing has demonstrated that the Cook Celect Vena Cava Filter is MR Conditional. It can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient field of 330 gauss/cm or less
- Maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 15 minutes of scanning
In non-clinical testing, the Cook Celect Vena Cava Filter produced a temperature rise of less than 0.2 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 15 minutes of MR scanning in a 3.0 Tesla MR system using a transmit/receive body coil MR scanner. MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the Cook Celect Vena Cava Filter. Therefore, it may be necessary to optimize MR imaging parameters for the presence of this metallic implant.
-
Zilver® Self-Expanding Stent
Non-clinical testing has demonstrated that the Zilver Self-Expanding Stent is MR Conditional. It can be scanned safely under the following conditions:
- Static magnetic field of 3 Tesla or less
- Spatial gradient field of 720 Gauss/cm or less
- Whole body averaged specific absorption rate (SAR) of 1.5 W/kg (for a single stent at 1.5 Tesla) and 3 W/kg (for a single stent at 3 Tesla and a pair of overlapping stents at 1.5 and 3 Tesla) for 20 minutes (for a single stent at 1.5 Tesla) and 15 minutes of scanning (for a single stent at 3 Tesla and a pair of overlapping stents at 1.5 and 3 Tesla), respectively.
In non-clinical testing, the Zilver Self-Expanding Stent produced maximum temperature rises of 0.1, 3.8, 0.8, and 0.1 degrees C (for a single stent at 1.5 Tesla, a pair of overlapping stents at 1.5 Tesla, a single stent at 3 Tesla, and a pair of overlapping stents at 3 Tesla, respectively) at whole body averaged specific absorption rates (SAR) of 1.5 W/kg (for a single stent at 1.5 Tesla) and 3 W/kg (for a single stent at 3 Tesla and a pair of overlapping stents at 1.5 and 3 Tesla) for 20 minutes (for a single stent at 1.5 Tesla) and 15 minutes (for a single stent at 3 Tesla and a pair of overlapping stents at 1.5 and 3 Tesla) of MR scanning in a 1.5 Tesla/64 MHz General Electric MR scanner, a 1.5 Tesla Magnetom Siemens Medical Solutions MR Scanner (to evaluate a pair of overlapping stents), and a 3 Tesla Excite General Electric MR scanner.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the Zilver Self-Expanding Stent. Therefore, it may be necessary to optimize MR imaging parameters for the presence of this metallic implant.
Heating in the MRI environment for stents with fractured struts is not known.
-
Embolization Coils - Stainless Steel
Stainless steel coils are ferrous and are affected by the MR field. Bench top testing on stainless steel embolization coil samples showed high degrees of torque and deflection. Therefore, stainless steel embolization coils have a designation of MR Unsafe and we would not recommend a patient implanted with a stainless steel embolization coil be scanned.
-
Gianturco-Roehm Bird’s Nest® Vena Cava Filter
MR-Safe, no additional risk to patients, but may affect the quality of the diagnostic information if scanning in the area of the filter.
MRI diagnostic procedrues should be postponed for 6 weeks following filter implantation to ensure device incorporation into the vessel wall.
-
Formula 418® Balloon Expandable Biliary Stent
Non-clinical testing has demonstrated that the Formula Biliary Stent is MR Conditional. A patient with this stent may undergo MRI immediately after placement under the following conditions:
- Static magnetic field of 3.0 Tesla or less
- Maximum spatial gradient magnetic field of 720 gauss/cm
- Maximum MR system reported whole body averaged specific absorption rate (SAR) of 3.0 W/kg for 15 minutes of scanning
In non-clinical testing, the Formula Biliary Stent produced a temperature rise of less than 1 degree C at an MR system reported maximum whole body averaged specific absorption rate (SAR) of 3 W/kg for 15 minutes of MR scanning in a 3 Tesla, Excite, Software G3.0-052B, General Electric Medical Systems MR scanner.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the Formula Biliary Stent. Therefore, it may be necessary to optimize MR imaging parameters for the presence of this metallic implant. The effect of heating in the MRI environment for overlapping stents or stents with fractured struts is unknown.
-
Günther Tulip™ Vena Cava Filter
Non-clinical testing has demonstrated that the Günther Tulip Vena Cava Filter is MR Conditional. It can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient field of 525 gauss/cm or less
- Maximum whole body averaged specific absorption rate (SAR) of 3.0 W/kg for 15 minutes of scanning
In non-clinical testing, the Günther Tulip Vena Cava Filter produced a temperature rise of less than 0.6 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 3.0 W/kg for 15 minutes of MR scanning in a 3.0 Tesla MR system using a transmit/receive body coil (Excite, Software G3.0-052B, General Electric Healthcare, Milwaukee, WI) MR scanner.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the Günther Tulip Vena Cava Filter. Therefore, it may be necessary to optimize MR imaging parameters for the presence of this metallic implant.
-
Hilal Embolization Microcoils™
Hilal Embolization Coils are manufactured from a platinum composition, which has been shown to have no ferromagnetic response. Through non-clinical testing, embolization coils manufactured of this material have been shown to be MR Conditional. A patient with one of these implants can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient field of 330 gauss/cm
- Maximum MR system whole-body-averaged specific absorption rate (SAR) of 3-W/kg for 15 minutes of scanning
In this testing, platinum embolization coils produced a temperature rise of greater than 0.5 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI. The effect of heating for other conditions, multiple coils or overlapping coils is unknown.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of platinum embolization coils.
-
Cook-Swartz Doppler Flow Probe
WARNING–MR UNSAFE
Do not expose patient to an MRI procedure while Cook-Swartz Doppler Flow Probe is implanted. Substantial MRI-related heating of the Doppler Flow Probe may occur. Doppler Flow Probe must be removed prior to any MRI procedure.
-
MReye® Embolization Coils
Through non-clinical testing, the MReye Embolization Coil has been shown to be MR Conditional. It can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient of 330 gauss/cm
- Maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI
The MReye Embolization Coil will not migrate in this MRI environment. Non-clinical testing has not been performed to rule out the possibility of device migration at static magnetic field strengths higher than 3.0 Tesla and a maximum spatial gradient higher than 330 gauss/cm.
In this testing, the MReye Embolization Coil produced a temperature rise of greater than or equal to 0.6 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI. The effect of heating in the MRI environment for other conditions, multiple coils or overlapping coils is unknown.
MRI image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the MReye Embolization Coil.
-
MReye Flipper® Detachable Embolization Coils
Through non-clinical testing, the MReye Flipper Detachable Embolization Coil Delivery System has been shown to be MR Conditional. It can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient of 330 gauss/cm
- Maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI
Embolization coils manufactured of Inconel will not migrate in this MRI environment. Non-clinical testing has not been performed to rule out the possibility of device migration at static magnetic field strengths higher than 3.0 Tesla and a maximum spatial gradient higher than 330 gauss/cm.
In this testing, the MReye Embolization Coil produced a temperature rise of greater than or equal to 0.6 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI. The effect of heating in the MRI environment for other conditions, multiple coils or overlapping coils is unknown.
MRI image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the MReye Embolization Coil.
-
MReye® Needles for Magnetic Resonance Imaging
Cook’s Interventional MReye needles are used for initial puncture and positioning control as well as biopsies and other interventional procedures in combination with Magnetic Resonance Imaging.
- MReye products are created from a non-ferromagnetic material that helps prevent disturbing artifacts.
- MReye needles are recommended for use with MRI scanners not exceeding 1.5 Tesla.
To see different-sized images of the needle, try these scanner parameters:
- To see an image of the needle at a ratio of 1:1, select a spin echo sequence (TR/TE 200 ms/15 ms).
- To see an image of the needle enlarged approximately 2:1, select a gradient echo sequence (TR/TE/Flip angle 336 ms/15 ms/90°).
-
Nester® Embolization Coils
Nester Embolization Coils are manufactured from a platinum composition, which has been shown to have no ferromagnetic response. Through non-clinical testing, embolization coils manufactured of this material have been shown to be MR Conditional. A patient with one of these implants can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient field of 330 gauss/cm
- Maximum MR system whole-body-averaged specific absorption rate (SAR) of 3-W/kg for 15 minutes of scanning
In this testing, platinum embolization coils produced a temperature rise of greater than 0.5 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI. The effect of heating for other conditions, multiple coils or overlapping coils is unknown.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of platinum embolization coils.
-
Tornado® Embolization Coils
Tornado Embolization Coils are manufactured from a platinum composition, which has been shown to have no ferromagnetic response. Through non-clinical testing, embolization coils manufactured of this material have been shown to be MR Conditional. A patient with one of these implants can be scanned safely immediately after placement under the following conditions:
- Static magnetic field strengths of 3.0 Tesla or less
- Maximum spatial gradient field of 330 gauss/cm
- Maximum MR system whole-body-averaged specific absorption rate (SAR) of 3-W/kg for 15 minutes of scanning
In this testing, platinum embolization coils produced a temperature rise of greater than 0.5 degrees C at a maximum whole body averaged specific absorption rate (SAR) of 2.0 W/kg for 20 minutes of MRI. The effect of heating for other conditions, multiple coils or overlapping coils is unknown.
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of platinum embolization coils.
-
Vital Port® System
Non-clinical testing demonstrated that the Vital-Port Vascular Access Ports are MR Conditional. A patient with one of these implants can be scanned safely immediately after placement under the following conditions:
- Static magnetic field of 3.0 Tesla or less
- Maximum spatial gradient magnetic field of 720 gauss/cm
- Maximum MR system reported whole-body-averaged specific absorption rate (SAR) of 3W/kg for 15 minutes of scanning
In non-clinical testing, the vascular access ports, produced maximum temperature increases of less than or equal to 0.7 degrees C at maximum MR system-reported whole body averaged specific absorption rate (SAR) of 3 W/kg for 15 minutes of MR scanning in a 3 Tesla MR system using a transmit/receive body coil (Excite, Software G3.0-052B, General Electric Healthcare, Milwaukee, WI).
MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the vascular access ports. Therefore, it may be necessary to optimize MR imaging parameters to compensate for the presence of one of these implants.
-
Zenith TX2® TAA Endovascular Graft
(excerpted from IFU)
Zenith TX2 MRI Compatibility Download
Non-clinical testing has demonstrated that the Zenith TX2 TAA Endovascular Graft is MR Conditional. It can be scanned safely under the following conditions:
1.5 Tesla Systems:
- Static magnetic field of 1.5 Tesla
- Spatial gradient field of 450 Gauss/cm
- Maximum whole-body-averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning
In non-clinical testing, the Zenith TX2 TAA Endovascular Graft produced a temperature rise of less than 1.4°C at a maximum whole-body-averaged specific absorption rate (SAR) of 2.8 W/kg for 15 minutes of MR scanning in a 1.5 Tesla Magnetom, Siemens Medical Magnetom MR scanner. The maximum whole-body-averaged specific absorption rate (SAR) was 2.8 W/kg, which corresponds to a calorimetry measured value of 1.5 W/kg.
3.0 Tesla Systems:
- Static magnetic field of 3.0 Tesla
- Spatial gradient field of 720 Gauss/cm
- Maximum whole-body-averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning
In non-clinical testing, the Zenith TX2 TAA Endovascular Graft produced a temperature rise of less than 1.9°C at a maximum whole-body-averaged specific absorption rate (SAR) at 3.0 W/kg for 15 minutes of MR scanning in a 3.0 Tesla, Excite, GE Electric Healthcare MR scanner. The maximum whole-body-averaged specific absorption rate (SAR) was 3.0 W/kg, which corresponds to a calorimetry measured value of 2.8 W/kg.
The image artifact extends throughout the anatomical region containing the device, obscuring the view of immediately adjacent anatomical structures within approximately 20 cm of the device, as well as the entire device and its lumen, when scanned in non-clinical testing using the sequence: Fast spin echo in a 3.0 Tesla, Excite, GE Electric Healthcare, with G3.0-052B software, MR system with body radiofrequency coil.
For all scanners, the image artifact dissipates as the distance from the device to the area of interest increases. MR scans of the lower extremities may be obtained without image artifact. Image artifact may be present in scans of the abdominal, upper extremity, and head and neck region, depending on distance from the device to the area of interest.
Clinical information is available on six patients who received MRI scans during the course of the clinical trial. There have been no reported adverse events or device problems in any of these patients as a result of having received an MRI. Additionally, there have been approximately 3,000 patients implanted with Zenith TAA Endovascular Grafts worldwide, in which there have been no reported adverse events or device problems as a result of MRI.
Cook recommends that the patient register the MR conditions disclosed in this IFU with the MedicAlert Foundation. The MedicAlert Foundation can be contacted in the following manners:
Mail: MedicAlert Foundation International
2323 Colorado Avenue
Turlock, CA 95382Phone: 888-633-4298 (toll free)
209-668-3333 from outside the USFax: 209-669-2450 Web: www.medicalert.org
Products Containing Latex
Some COOK product packaging contains a Natural Rubber latex warning on the label. These products contain Latex that can be contacted directly or indirectly with normal use of our product. An example of indirect contact is when a fluid contacts the Latex and subsequently comes in contact with the patient. Additionally, we assure that our packaging materials do not contain Latex.
Please contact Customer Service or your local sales representative if you have further questions.